UL Hinweise - Compact Motion

Application

The modules are intended for use with Beckhoff’s UL Listed EtherCAT System only.

Examination

For cULus examination, the Beckhoff I/O System has only been investigated for risk of fire and electrical shock (in accordance with UL508 and CSA C22.2 No. 142).

For devices with Ethernet connectors

Not for connection to telecommunication circuits.

Notes on motion devices

  • Motor overtemperature
    Motor overtemperature sensing is not provided by the drive.
  • Application for compact motion devices
    The modules are intended for use only within Beckhoff’s Programmable Controller system Listed in File E172151.
  • Galvanic isolation from the supply
    The modules are intended for operation within circuits not connected directly to the supply mains (galvanically isolated from the supply, i.e. on transformer secondary).
  • Requirement for environmental conditions
    For use in Pollution Degree 2 Environment only.

Grundlagen

UL-Zertifikation nach UL508. Solcherart zertifizierte Geräte sind gekennzeichnet durch das Zeichen:

UL Hinweise - Compact Motion 1:

Anwendung

Werden eingeschränkt zertifizierte Klemmen verwendet, ist die Stromaufnahme bei 24 VDC entsprechend zu beschränken durch Versorgung

  • von einer isolierten, mit einer Sicherung (entsprechend UL248) von maximal 4 A geschützten Quelle, oder
  • von einer Spannungsquelle die NEC class 2 entspricht.
    Eine Spannungsquelle entsprechend NEC class 2 darf nicht seriell oder parallel mit einer anderen NEC class 2 entsprechenden Spannungsquelle verbunden werden!

Diese Anforderungen gelten für die Versorgung aller EtherCAT Buskoppler, Netzteilklemmen, Busklemmen und deren Power-Kontakte.